sIRoPAD Scanner

Automated Analysis of Thousands of Plastic Particles

sIRoPAD automated Analysis of Plastic Particles
© IoSys


The sIRoPAD Scanner uses established near-infrared (NIR) spectroscopy to automatically and non-destructively identify large quantities of plastic particles. Thousands of samples can be analyzed in just a few minutes.  Each particle is captured individually while meaningful statistics are generated simultaneously for the entire bulk sample. The results can be presented graphically, in tabular form, or as a report and are documented. This saves time and money while supporting quality assurance in recycling and plastics processing facilities.

Automated Analysis Instead of Individual Measurements

While benchtop and handheld spectrometers typically analyze individual samples one after another, the sIRoPAD Scanner examines thousands of particles fully automatically in a single run. The system identifies the type of plastic for each particle and provides overall statistics for the bulk sample, as well as individual measurements for each particle.

After scanning, particles of interest, such as contaminants, can be targeted, reanalyzed, and marked on the measurement table with an LED laser. This makes them easier to remove or examine separately. Larger sample quantities can be analyzed in multiple runs and then combined into a single batch.

Benefits of the sIRoPAD Scanner at a Glance

  • Proven analysis method: Non-destructive identification of plastic types using established NIR spectroscopy.
  • High sample throughput: Captures thousands of plastic particles in a fully automated measurement run.
  • Suitable for many sample types: Analyzes flakes, granules, pellets, and regrind.
  • Automatically evaluate batches: Generates statistics for the entire bulk sample.
  • Capture each particle individually: Reports the plastic type separately for each analyzed particle.
  • Quickly view results: Displays the entire scan area clearly and color-coded.
  • Locate conspicuous particles: Re-scans selected particles and marks them directly on the measurement table using an LED laser.
  • Monitor quality: Supports purity testing, incoming goods inspection, and complaint handling.
  • Save time & costs: Automates the analysis of large sample volumes and reduces the number of manual individual measurements.
Technical Details
Measurement Principle Non-destructive NIR spectroscopy
Weight 14 kg (measurement table with analyzer, without computer and monitor)
Dimensions 815 x 595 x 384 mm (measuring table with analyzer, without computer and monitor)
Measurement Mode Diffuse Reflection
Scan mode X/Y raster scan over an area of up to 50 x 33 cm
Software ICM analysis software for Windows
Data Output Graphical and tabular output, Excel export, mini-plotter, or printer
Operating Temperature 10 °C to 35 °C
Power supply 100 to 230 V AC, 50/60 Hz
Manufacturer IoSys-Seidel, Ratingen

Applications

  • Sorting inspections at recycling facilities
  • Quality assurance at plastics processing facilities
  • Incoming and outgoing goods inspection
  • Complaint handling and support for acceptance decisions
  • Detection of macro- and microplastics in research and development projects

Frequently Asked Questions

How does the sIRoPAD scanner work?

The scanner, which uses near-infrared (NIR) light, is mounted above the measuring table. It illuminates the samples and measures the reflection in the NIR spectral range. Since different types of plastic have unique NIR absorption spectra, the system can identify the type of plastic based on the reflected light.

Do I need to be a spectroscopy expert to operate the system?

No, the software is designed to be intuitive. It automatically performs analysis using the built-in spectral database.

What types of plastics can the sIRoPAD scanner analyze?

Pure plastics:
PET, PE, PP, PVC, PS, ABS, PA, PC, PBT, SAN, PMMA, POM, PPO, cellulose, and PLA.

Blends:
PC+ABS, PVC+ABS, PC+PET, PE+PET, PE+PA, and PP+PET.

Can the sIRoPAD scanner identify black plastics?

No. Black samples do not reflect enough light, so the detector does not receive enough usable signals. For black plastics, methods such as FT-IR or the mIRoSpark’s sliding spark atomic emission spectroscopy (SS-OES) are suitable.

What is the minimum particle size?

Particles 1 mm or larger can be analyzed.

Can individual particles from the bulk sample be examined specifically?

Yes, selected particles, such as contaminants, can be retargeted and analyzed using the software. An LED laser marks the particle on the measurement table, enabling manual removal.

How reliable is this analytical method?

NIR spectroscopy has been used for years in laboratories and sorting facilities to identify different types of plastic.

How long does an analysis take?

A typical measurement run with 200 grams of bulk material takes about 15 minutes. The process is fully automated.

Does the system require maintenance or calibration?

The system is maintenance-free. It performs self-calibration using the included ceramic and PA6 standards.

What services are offered?

The sIRoPAD scanner is manufactured in Germany. The manufacturer provides remote support during regular business hours.

Do you have questions?

Are you interested in the sIRoPAD?